You are here

ENR CTIO 1.5-m 2023-04-23

Primary tabs

Date: 
Sunday, April 23, 2023
Telescope: 
CTIO 1.5-m
Submitter: 
Jacqueline Seron
Observer Support: 
None
Night Assistant: 
Jackie Seron
Problems: 

Expmeter failed at 0:15 UT (red led in Chiron GUI), init switch didn’t work, I restarted Chiron GUI, but I kept seeing an error message, I pressed the init switch again and that seemed to work.
At the end of the night I saw again at 5:39 UT “GUI ERROR ON COMMAND EXPM send threshold 8000000000.000 … TIME OUT …” What does it mean? How can I correct this? Thanks!.

J110949.35-521018.7 guider failed to keep the star centered ( I used a star in the corner as the target has a close companion), I stopped the exposure (1129) and took another one that should be fine (1130).

 

 

Comments: 

Program completed

Please ignore image 1123.

RINGSS didn’t work tonight, I used DECam seeing values

 
Conditions: 
General Conditions
Temperature Max: 
11.00
Temperature Min: 
9.00
Humidity Max: 
60
Humidity Min: 
45
Wind Speed Max: 
7.00
Wind Speed Min: 
1.00
Comment: 
Clouds close to the horizon for most of the night.
1st Quarter
Clouds: 
Cirrus
Wind: 
Low
Seeing Value: 
1.30
Seeing Variability: 
0.2
Seeing Source: 
Other
Sky : 
3
2nd Quarter
Clouds: 
Cirrus
Wind: 
Low
Seeing Value: 
1.20
Seeing Variability: 
0.4
Seeing Source: 
Other
Sky: 
1
3rd Quarter
Clouds: 
Cirrus
Wind: 
Low
Seeing Value: 
1.30
Seeing Variability: 
0.2
Seeing Source: 
Other
Sky: 
1
4th Quarter
Clouds: 
Cirrus
Wind: 
Medium
Seeing Value: 
1.40
Seeing Variability: 
0.2
Seeing Source: 
Other
Sky: 
1
Program: 
Target of Oportunity: 
No
Time Observed: 
10.0
Time Engineering: 
0.0
Time lost technical: 
0.0
Time lost weather: 
0.0
Time lost other: 
0.0
Primary Investigator: 
Todd Henry
Institution: 
SMARTS
Instrument: 
CTIO 1.5m Echelle
Organization: 
SMARTS
Total Program Time: 
10
Total Times Time Observed Time Engineering Time lost technical Time lost weather Time lost other Total Program Time
2023-04-23 10.0 0.0 0.0 0.0 0.0 10