CERRO TOLOLO INTER-AMERICAN OBSERVATORY INSTRUMENT SECTION FILTER TRANSMISSION SCANNER FILTER IDENTIFICATION 5024/15 DATE OF MEASUREMENT FILTER SIZE 2 X 2 X .136 INCH FOCAL RATIO 13.5 TEMPERATURE [C] 22 PEAK WAVELENGTH [A] 5026 PEAK TRANSMISSION [%] 43.632 CENTER WAVELENGTH [A] 5025.5 BANDWIDTH [A] 15 COMMENTS: 5024/15 SFI WAVELENGTH TRANSMISSION 4970 .0294464 4972 .0294118 4974 .0589449 4976 .0588928 4978 .11782 4980 .117682 4982 .117994 4984 .117578 4986 .147449 4988 .176887 4990 .176574 4992 .235641 4994 .294464 4996 .353774 4998 .412979 5000 .529879 5002 .737463 5004 1.00325 5006 1.35693 5008 1.8818 5010 2.70429 5012 4.41176 5014 7.23529 5016 12.0624 5018 21.229 5020 30.9685 5022 38.9461 5024 42.7013 5026 43.6321 5028 42.0478 5030 36.5458 5032 26.7552 5034 18.8846 5036 11.9209 5038 7.72633 5040 4.95575 5042 3.06513 5044 2.12577 5046 1.41593 5048 1.09241 5050 .82669 5052 .619469 5054 .531758 5056 .384047 5058 .295683 5060 .236337 5062 .177305 5064 .177357 5066 .14771 5068 .118273 5070 .118308 .