1. TCS Interface problem:
23:52:47 UT, the following warnings were seen:
WARNING: These components are not ready for exposure: TCSINTERFACE
WARNING: Interlock SISPI (OCS) is now broken
WARNING: Interlock DECAM (SISPI) is now broken
Telescope operator restarted TCS and SISPI was reset in the observer interface. Smooth operation until problem #2 below:
2.About 09:45 UT: TCS failed again (this time without an alarm or warning on the Observer console; was caught by the Telescope Operator). Observers stopped the queue while telescope operator investigated and corrected the error. An image was being executed at that time, got frozen and then it suddenly finished, leading to image 327630 apparently exposing while the telescope was moving (leading to visible trails on image 327630).
Only after exposure 327630 had started did the Observer console report an error, but only about the guiding (continuous null centroid limits exceeded).
Queue was restarted after that incident with no further problems.
Total Times | Time Observed | Time Engineering | Time lost technical | Time lost weather | Time lost other | Total Program Time |
---|---|---|---|---|---|---|
2014-06-20 | 11.5 | 0.0 | 0.0 | 0.0 | 0.0 | 11.5 |
Links
[1] mailto:rmr@astro.ucla.edu
[2] http://www.ctio.noao.edu/noao/field-collection/field-nr-prog/1606/delete?destination=print/node/5839
[3] http://www.ctio.noao.edu/noao/field-collection/field-nr-prog/1606/edit?destination=print/node/5839
[4] http://www.ctio.noao.edu/noao/field-collection/field-nr-prog/add/node/5839?destination=print/node/5839
None.